2

Share:


dBadge2 Personal Noise Exposure Meter



PERSONAL NOISE EXPOSURE MONITORING SOLUTION

dBadge2 Personal Noise Exposure Meter

The dBadge2 Personal Noise Exposure Meter is a shoulder-worn dose meter designed for workplace noise exposure measurements. It captures all workplace noise parameters simultaneously and supports accurate personal noise monitoring, strong internal storage, event audio recording, extended run time, IP65 protection, and dependable occupational noise assessment performance.

Core Monitoring Capability

Shoulder Worn Dose Meter

All Workplace Noise Parameters Simultaneously

300 Hours Run Data Storage

Typically 35 Hours Broadband Runtime

Key Features

Simultaneous Noise Parameter Measurement

The dBadge2 measures all workplace noise parameters simultaneously, making it suitable for comprehensive occupational noise exposure monitoring in one measurement run.

Wide Operating and Peak Ranges

Supports 55.0-140.3 dB(A) RMS linear operating range and 90.0-143.3 dB peak measurement range with C or Z weighting.

Strong Internal Storage Capacity

Internal USB flash memory stores up to 300 hours of run data, including 1-second profile data, and up to 90 minutes of event audio recording.

Long Runtime Performance

The meter typically provides 35 hours using Broadband Mode and typically 15 hours using Octave mode, supporting extended workplace monitoring sessions.

Multiple Weighting Options

Supports A, C and Z Type 2 frequency weightings, Fast, Slow and Impulse time weightings, and Q=3 or Q=5 dB exchange rates.

IP65 Workplace Protection

The compact 117g unit includes an IP65 environmental rating with a permeable air vent, supporting practical use in demanding workplace environments.

dBadge2 Technical Specifications

Standards ANSI S1.25:1991 R2007, IEC 61252 Ed 1.1 (2002-3)
Linear Operating Range 55.0-140.3 dB(A) RMS
Peak Measurement Range 90.0-143.3 dB, C or Z weighted
Sound Exposure Range 0.0-6,100.0 Pa²Hours
Frequency Weightings A, C and Z, Type 2
Time Weightings Fast, Slow and Impulse
Exchange Rate Q=3 or Q=5 dB exchange rates
Threshold and Criterion 70-90 dB in 1 dB steps
Operating Temperature Range 0°C to +40°C for <±0.5 dB error limit / -10°C to +50°C for <±0.8 dB error limit
Ambient Pressure Range <±0.5 dB over 85-112 kPa
Humidity Range <±0.5 dB over 30%-90%, non-condensing
Storage Temperature Range -10°C to +50°C
Battery Internal NiMH, 800mAH
Run Time Typically 35 hours using Broadband Mode / Typically 15 hours using Octave mode
Charge Time <6 hours from fully discharged
Maximum Run Duration 24 hours
Maximum Number of Runs 100
Storage Capacity Internal USB flash memory - 300 hours of run data including 1 second profile data and up to 90 minutes of event audio recording
PC Interface USB 2.0 Full speed 12Mbps via Docking Station
Dimensions 85L x 54W x 55H mm
Weight 117g
Environmental I.P. Rating IP65 with permeable air vent

Performance and Workplace Operation

Broad Noise Measurement Coverage

With 55.0-140.3 dB(A) RMS linear operating range, 90.0-143.3 dB peak range, and 0.0-6,100.0 Pa²Hours sound exposure range, the dBadge2 supports many occupational environments.

Run Duration and Data Capacity

Supports up to 24 hours maximum run duration, 100 maximum runs, 300 hours run data, and up to 90 minutes event audio recording.

Docking Station Data Transfer

PC interface is supported through USB 2.0 Full speed 12Mbps via Docking Station for practical data transfer and device management.

Physical, Power and Environmental Details

Compact Shoulder Worn Design

  • Dimensions: 85L x 54W x 55H mm
  • Weight: 117g
  • Designed as a shoulder-worn dose meter
  • IP65 rating with permeable air vent

Battery and Charging

  • Battery: internal NiMH, 800mAH
  • Typically 35 hours in Broadband Mode
  • Typically 15 hours in Octave mode
  • Charge time: <6 hours from fully discharged

Environmental Conditions

  • Operating temperature: 0°C to +40°C for <±0.5 dB error limit
  • Operating temperature: -10°C to +50°C for <±0.8 dB error limit
  • Ambient pressure: 85-112 kPa
  • Humidity: 30%-90% non-condensing
  • Storage temperature: -10°C to +50°C

Designed for Personal Workplace Noise Exposure Measurement

dBadge2 Personal Noise Exposure Meter helps occupational hygienists, workplace safety teams, environmental health professionals, consultants, and compliance teams measure personal noise exposure accurately and efficiently.

Typical Applications

Workplace Noise Exposure Measurements

Personal Occupational Noise Dose Monitoring

Industrial Hygiene Noise Assessments

Health and Safety Sound Monitoring

Shift-Based Employee Noise Tracking

Simultaneous Noise Parameter Measurement

Event Audio Recording During Runs

Broadband and Octave Mode Monitoring

Compliance Noise Documentation

Personal Sound Exposure Reporting



 Inquiry - dBadge2 Personal Noise Exposure Meter