Core Monitoring Capability
Shoulder Worn Dose Meter
All Workplace Noise Parameters Simultaneously
300 Hours Run Data Storage
Typically 35 Hours Broadband Runtime
Key Features
Simultaneous Noise Parameter Measurement
The dBadge2 measures all workplace noise parameters simultaneously, making it suitable for comprehensive occupational noise exposure monitoring in one measurement run.
Wide Operating and Peak Ranges
Supports 55.0-140.3 dB(A) RMS linear operating range and 90.0-143.3 dB peak measurement range with C or Z weighting.
Strong Internal Storage Capacity
Internal USB flash memory stores up to 300 hours of run data, including 1-second profile data, and up to 90 minutes of event audio recording.
Long Runtime Performance
The meter typically provides 35 hours using Broadband Mode and typically 15 hours using Octave mode, supporting extended workplace monitoring sessions.
Multiple Weighting Options
Supports A, C and Z Type 2 frequency weightings, Fast, Slow and Impulse time weightings, and Q=3 or Q=5 dB exchange rates.
IP65 Workplace Protection
The compact 117g unit includes an IP65 environmental rating with a permeable air vent, supporting practical use in demanding workplace environments.
dBadge2 Technical Specifications
| Standards | ANSI S1.25:1991 R2007, IEC 61252 Ed 1.1 (2002-3) |
| Linear Operating Range | 55.0-140.3 dB(A) RMS |
| Peak Measurement Range | 90.0-143.3 dB, C or Z weighted |
| Sound Exposure Range | 0.0-6,100.0 Pa²Hours |
| Frequency Weightings | A, C and Z, Type 2 |
| Time Weightings | Fast, Slow and Impulse |
| Exchange Rate | Q=3 or Q=5 dB exchange rates |
| Threshold and Criterion | 70-90 dB in 1 dB steps |
| Operating Temperature Range | 0°C to +40°C for <±0.5 dB error limit / -10°C to +50°C for <±0.8 dB error limit |
| Ambient Pressure Range | <±0.5 dB over 85-112 kPa |
| Humidity Range | <±0.5 dB over 30%-90%, non-condensing |
| Storage Temperature Range | -10°C to +50°C |
| Battery | Internal NiMH, 800mAH |
| Run Time | Typically 35 hours using Broadband Mode / Typically 15 hours using Octave mode |
| Charge Time | <6 hours from fully discharged |
| Maximum Run Duration | 24 hours |
| Maximum Number of Runs | 100 |
| Storage Capacity | Internal USB flash memory - 300 hours of run data including 1 second profile data and up to 90 minutes of event audio recording |
| PC Interface | USB 2.0 Full speed 12Mbps via Docking Station |
| Dimensions | 85L x 54W x 55H mm |
| Weight | 117g |
| Environmental I.P. Rating | IP65 with permeable air vent |
Performance and Workplace Operation
Broad Noise Measurement Coverage
With 55.0-140.3 dB(A) RMS linear operating range, 90.0-143.3 dB peak range, and 0.0-6,100.0 Pa²Hours sound exposure range, the dBadge2 supports many occupational environments.
Run Duration and Data Capacity
Supports up to 24 hours maximum run duration, 100 maximum runs, 300 hours run data, and up to 90 minutes event audio recording.
Docking Station Data Transfer
PC interface is supported through USB 2.0 Full speed 12Mbps via Docking Station for practical data transfer and device management.
Physical, Power and Environmental Details
Compact Shoulder Worn Design
- Dimensions: 85L x 54W x 55H mm
- Weight: 117g
- Designed as a shoulder-worn dose meter
- IP65 rating with permeable air vent
Battery and Charging
- Battery: internal NiMH, 800mAH
- Typically 35 hours in Broadband Mode
- Typically 15 hours in Octave mode
- Charge time: <6 hours from fully discharged
Environmental Conditions
- Operating temperature: 0°C to +40°C for <±0.5 dB error limit
- Operating temperature: -10°C to +50°C for <±0.8 dB error limit
- Ambient pressure: 85-112 kPa
- Humidity: 30%-90% non-condensing
- Storage temperature: -10°C to +50°C
Designed for Personal Workplace Noise Exposure Measurement
dBadge2 Personal Noise Exposure Meter helps occupational hygienists, workplace safety teams, environmental health professionals, consultants, and compliance teams measure personal noise exposure accurately and efficiently.
Typical Applications
Workplace Noise Exposure Measurements
Personal Occupational Noise Dose Monitoring
Industrial Hygiene Noise Assessments
Health and Safety Sound Monitoring
Shift-Based Employee Noise Tracking
Simultaneous Noise Parameter Measurement
Event Audio Recording During Runs
Broadband and Octave Mode Monitoring
Compliance Noise Documentation
Personal Sound Exposure Reporting
Inquiry - dBadge2 Personal Noise Exposure Meter