2

Share:


CEL-630 (Class 1 & Class 2) S Environment Sound Level Meter



ENVIRONMENT AND OCCUPATIONAL SOUND LEVEL METER

CEL-630 Class 1 & Class 2 Sound Level Meter

The CEL-630 Class 1 & Class 2 is an advanced environment sound level meter range designed for occupational and environmental noise monitoring. It combines simple operation with advanced functionality, broad measurement capability, octave and 1/3 octave analysis, audio recording, extended data logging, and simultaneous workplace and environmental noise parameter monitoring.

Core Measurement Capability

IEC61672 Class 1 and Class 2

20- 140 dB RMS Measurement Range

Octave and 1/3 Octave Analysis

2GB Memory for Long-Term Logging

Key Features

Standards-Based Sound Measurement

Supports IEC61672:2002 Class 1 and Class 2 and ANSI S1.4 Type 1 and 2, making it suitable for professional occupational and environmental noise measurement.

Simultaneous Weightings

Measures Fast, Slow and Impulse time weightings simultaneously, together with A, C and Z frequency weightings for efficient sound data capture.

Octave and 1/3 Octave Analysis

Supports 11 octave bands from 16Hz-16kHz for B and C models, and 33 octave bands from 12.5Hz-20kHz for K models.

Extended Logging Capacity

Includes 2GB memory for more than 1 year of logging at 1 second intervals, supporting 999 runs and long-term monitoring up to 400 days.

Audio Event Recording

Supports 10 hours of high-quality audio recording and 60 hours of low-quality audio recording, with up to 999 events per run.

Simple Multilingual Interface

The interface supports English, French, German, Spanish, Italian, Portuguese, and Chinese for easier field operation across different users.

CEL-630 Technical Specifications

Standards IEC61672:2002 Class 1 and 2, ANSI S1.4 Type 1 and 2 (1983)
Filters IEC61260 Class 0, ANSI S1.43 (1996)
Standards Note IEC61672 replaces IEC60651 and IEC60804
Measurement Range 20-140 dB RMS, 143.3dB peak
Total Noise Floor 19dB(A) Class 1, 25dB(A) Class 2
Time Weightings Fast, Slow and Impulse simultaneously
Frequency Weightings A, C and Z un-weighted simultaneously
Frequency Bands 11 octave bands 16Hz-16kHz for B and C models / 33 octave bands 12.5Hz-20kHz for K models
Amplitude Weighting Q=3, 4 and 5 simultaneously
Back Erase Last 10 seconds in cumulative mode, all models
Timers Duration 1 second to 24 hours
On / Off Timers 6 sets with selectable times and repeat function
Tripod Mount 1/4" Whitworth socket
Batteries 3 x AA Alkaline, 10-15 hours depending on backlight
External Power 9-14V DC at 150mA
Weight 332g including batteries
Size 230 x 72 x 31mm including preamp and microphone
Operating Humidity 0 to 90% RH without condensation
Temperature -10 to +50°C Class 1 / 0 to 40°C Class 2
Atmospheric Pressure 65 to 108kPa

Measured Parameters and Analysis

Broad Noise Parameters

Measures key values including Lxy, Lmax, Lmin, Lavg, Lpeak, LAE, LC-A, Leq, L10, L90, and related workplace dose values calculated within insight software.

Octave and 1/3 Octave Values

Supports octave and 1/3 octave values including Lxy, Lmax, Lmean and 5x Ln% on CEL-633, with frequency weightings A, C or Z and time weightings F, S or I.

CEL-633 Advanced Logging

The CEL-633 model stores 5x L values in broadband and octave modes, plus all parameters for period times and 6 selectable profile parameters.

Memory, Logging and Audio Recording

Long-Term Memory and Logging

  • 2GB memory
  • More than 1 year logging at 1 second interval
  • 999 runs supported
  • All parameters stored and accessible via Casella Insight
  • Long-term unattended monitoring up to 400 days

Audio Recording and Events

  • 999 events per run
  • 10 hours audio recording in high quality mode
  • 60 hours audio recording in low quality mode
  • Daily new run support for unattended monitoring

Audio Quality Options

  • Low Quality: 8,000 samples/s at 8bit, 64kb/s, up to 4kHz
  • High Quality: 24,000 samples/s at 8bit, 192kb/s, up to 12kHz

Physical, Power and Environmental Details

Portable Field Design

  • Size: 230 x 72 x 31mm including preamp and microphone
  • Weight: 332g including batteries
  • Tripod mount: 1/4" Whitworth socket

Battery and External Power

  • Batteries: 3 x AA Alkaline
  • Battery runtime: 10-15 hours depending on backlight
  • External power: 9-14V DC at 150mA

Environmental Operating Conditions

  • Humidity: 0 to 90% RH without condensation
  • Temperature: -10 to +50°C Class 1
  • Temperature: 0 to 40°C Class 2
  • Atmospheric pressure: 65 to 108kPa

Designed for Occupational and Environmental Noise Monitoring

CEL-630 Class 1 & Class 2 helps occupational hygienists, environmental consultants, workplace safety teams, acoustic surveyors, and compliance professionals collect reliable sound level data with advanced analysis, logging, and audio recording capability.

Typical Applications

Occupational Noise Monitoring

Environmental Noise Assessment

Workplace Sound Exposure Analysis

Octave and 1/3 Octave Analysis

Long-Term Unattended Noise Logging

Audio Event Recording

Compliance-Focused Sound Measurement

Industrial Hygiene Noise Evaluation

Portable Field Sound Studies

Professional Sound Trend Reporting



 Inquiry - CEL-630 (Class 1 & Class 2) S Environment Sound Level Meter